Airwell Mega Tool Software
Original author(s) | Masatoshi Nei, Sudhir Kumar, Koichiro Tamura, Glen Stecher, Daniel Peterson, Nicholas Peterson |
---|---|
Developer(s) | Pennsylvania State University |
Initial release | 1993; 28 years ago |
Stable release | 10.2.5 / March 30, 2021; 4 months ago[1] |
Preview release | |
Operating system | Windows, OS X, Linux |
Platform | x86, x86-64 |
Available in | English |
Type | Bioinformatics |
License | |
Website | www.megasoftware.net |
Molecular Evolutionary Genetics Analysis (MEGA) is computer software for conducting statistical analysis of molecular evolution and for constructing phylogenetic trees. It includes many sophisticated methods and tools for phylogenomics and phylomedicine. It is licensed as proprietaryfreeware. The project for developing this software was initiated by the leadership of Masatoshi Nei in his laboratory at the Pennsylvania State University in collaboration with his graduate student Sudhir Kumar and postdoctoral fellow Koichiro Tamura.[2] Nei wrote a monograph (pp. 130) outlining the scope of the software and presenting new statistical methods that were included in MEGA. The entire set of computer programs was written by Kumar and Tamura. The personal computers then lacked the ability to send the monograph and software electronically, so they were delivered by postal mail. From the start, MEGA was intended to be easy-to-use and include solid statistical methods only.
MEGA version 2 (MEGA2), which was coauthored by an additional investigator Ingrid Jakobson, was released in 2001.[3] All the computer programs and the readme files of this version could be sent electronically due to advances in computer technology. Around this time, the leadership of the MEGA project was taken over by Kumar (now at Temple University) and Tamura (now at Tokyo Metropolitan University). The monograph Molecular Evolutionary Genetics Analysis was often used as a textbook for new ways to study molecular evolution.
MEGA has been updated and expanded several times and currently all these versions are available from the MEGA website. The latest release, MEGA7, has been optimized for use on 64-bit computing systems. MEGA is in two version. A graphical user interface is available as a native Microsoft Windows program. A command line version, MEGA-Computing Core (MEGA-CC), is available for native cross-platform operation. The method is widely used and cited. With millions of downloads across the releases, MEGA is cited in more than 85,000 papers. The 5th version has been cited over 25,000 times in 4 years.[4]
Release history[edit]
- Airwell mega tool software Untitled Where is serial number on lifeproof case Pour latte art advanced barista technique handbook 44 Download lrc player Local natives gorilla manor album download Korean traditional instrumental music mp3 Nvidia pixel shader 3.0 Huawei u8950-1 firmware Gvox encore 5 full size.
- Media Creation Tool 21H1 (10.0.19041.572) on 32-bit and 64-bit PCs. This download is licensed as freeware for the Windows (32-bit and 64-bit) operating system on a laptop or desktop PC from disk management without restrictions. Media Creation Tool 21H1 (10.0.19041.572) is available to all software users as a free download for Windows.
Airwell Mega Tool Software; Manuale D`uso Mercedes Ml 320 Cdi; Digitech Rp500 Patch Library; Microsoft Toolkit 2.4.7 (Activation Office 2013 Windows 8).
Version | Release date |
---|---|
1.0 | 1993[2] |
1.1 | 1994[6] |
2.0 | 2000[3] |
2.1 | 2001[3] |
3.0 | 2004[7] |
4.0 | 2006[8] |
4.1 | 2008[8] |
5.0 | 2011[9] |
5.1 | Oct 2012[9] |
5.2 | April 2013[9] |
6.0 | December 2013[4] |
7.0 | January 2016[10] |
10.0 (X) | May 2018[11] |
Features[edit]
Sequence alignment construction[edit]
- Alignment editor
- Sequencer (trace) file editor-viewer
- Integrated web browser, sequence fetching
Data handling[edit]
- Handling ambiguous states: R, Y, T, etc.
- Extended MEGA format to save all data attributes
- Importing data from other formats: Clustal, Nexus, etc.
- Data explorers
- Visual specification of domains-groups
Genetic code table section[edit]
- Add-edit user defined tables
- Compute statistical attributes of a code table
- Include all known code tables
Real-time caption expert engine[edit]
- Generate captions for distance matrices, phylogenies, tests, alignments
- Copy captions to external programs
Integrated text file editor[edit]
- Columnar block selection-editing
- Line numbers
- Utilities to format sequences, reverse complement etc.
Sequence data viewer[edit]
- Data export
- Highlighting
- Statistical quantities estimation
MCL-based estimation of nucleotide substitution patterns[edit]
- 4x4 rate matrix
- Transition-transversion rate ratios: k1, k2
- Transition-transversion rate bias: R
Substitution pattern homogeneity test[edit]
- Composition distance
- Disparity index
- Monte-carlo test
Distance estimation methods[edit]
- Nucleotide-by-nucleotide
- Synonymous-nonsynonymous: codon-by-codon
- Protein distance
- Distance calculations
- Sequence diversity calculations
- Variance calculations
Tests of selection[edit]
- Large sample Z-test
- Fisher’s exact test
- Tajima’s neutrality test
Molecular clock test[edit]
- Tajima’s relative rate test
Tree-making methods[edit]
- Minimum evolution method
- UPGMA
- Bootstrap phylogeny test
- Confidence probability test
- Distance matrix viewer
Tree explorers[edit]
- Phylogeny display
- Divergence time estimation
- Tree editing
- Change tree size
- Multiple tree display
External links[edit]
References[edit]
- ^ ab'Update History'. megasoftware.net. Retrieved 2021-04-19.
- ^ abKumar, S., K. Tamura, and M. Nei (1993) MEGA: Molecular Evolutionary Genetics Analysis. Ver. 1.0, The Pennsylvania State University, University Park, PA.
- ^ abcKumar, S., K. Tamura, I. B. Jakobsen, and M. Nei (2001) MEGA2: Molecular Evolutionary Genetics Analysis. Ver. 2.0, Bioinformatics 17:1244-1245.
- ^ abTamura, K., Stecher, G., Peterson, D., Filipski, A., Kumar, S. (2013) MEGA6: Molecular Evolutionary Genetics Analysis Version 6.0. Mol. Biol. Evol. 30:2725-2729.
- ^'MEGA Update History'. MEGA: Molecular Evolutionary Genetics Analysis. Retrieved 20 June 2013.
- ^Kumar, S., K. Tamura, and M. Nei (1994) MEGA: Molecular Evolutionary Genetics Analysis software for microcomputers. CABIOS 10:189-191.
- ^Kumar, S., Tamura, K., and Nei, M. (2004) MEGA3: Molecular Evolutionary Genetics Analysis. Brief. Bioinformatics 5:150-163.
- ^ abTamura, K., Dudley, J., Nei, M., Kumar, S. (2007) MEGA4: Molecular Evolutionary Genetics Analysis. Mol. Biol. Evol. 24(8):1596-1599.
- ^ abcTamura, K., Peterson, D., Peterson, N., Stecher, G., Nei, M., Kumar, S. (2011) MEGA5: Molecular Evolutionary Genetics Analysis using Maximum Likelihood, Evolutionary Distance, and Maximum Parsimony Methods. Mol. Biol. Evol. 28:2731-2739.
- ^Kumar, S., Stecher, G., & Tamura, K. (2016). MEGA7: Molecular Evolutionary Genetics Analysis version 7.0 for bigger datasets. Mol. Biol. Evol. 33(7):1870–1874.
- ^Kumar, S., Stecher, G., Li M., Knyaz C. & Tamura, K. (2018). MEGA X: Molecular Evolutionary Genetics Analysis across computing platforms. Mol. Biol. Evol. 35(6):1547-1549.
The newest ODIS software has been updated to V5.26 which works with VAS6154 and VAS5054A on Win 7 & Win 10 32 bit/64 bit.
What’s new in ODIS 5.26?
(1)ODIS Software Version: 5.26 for Full Brand till 2019.12 (also includes 5.16 for each brand till 2019.8)
(2)ETKA: 8.0 (2018.11)
(3)Elsawin: 6.0 (2016.1)
(4)ODIS Engineering: 11.0
(5)VCDS Software Version: 19.6.2
(6)OS System: Win7, Win10 32bit/ 64bit
The old software version all come with win7 system, most of customers know that the VAS5054A doesn’t support to use with win10 system, but with this 5.26 version is ok to use on Win10.
(7)Multi-Languages:
English/Japanese/Portuguese/Romanian/Korean/Dutch/Polish/Turkish/Spanish/French/Italian
Croatian/Danish/German/Swedish/Finnish/Slovenian/Czech/Russian/Greek/Chinese
(8)Support Vehicles: VAG Group includes Volkswagen (Shanghai VW, FAW-VW, VW Commercial Vehicles etc.), Audi, Lamborghini, Bentley, Skoda, Seat, Bugatti, MAN total 11 brands.
(9)Compatible Hardware: VAS5054A (Item No.SP33-B, SP33-BO), VAS6154A
Where to download ODIS 5.26 Postsetup 98.0.160?
The download links offered below are testing ok, no dead links.
Torrent 1
Size: 18KB
0.MS_Visual_C++2010 for W10
0.Prerequirements x64 W7
0.Prerequirements x86 W7
1.OffboardDiagSetup-Service_VWMCD_5_2_6-B52_6_0_2
2.ODIS-S 5.2.6 Patch+License-Full After Unrar this the password for the 7zip archive is as alwaysfantomel
3.PDU-API_fix_x86+x64 for W10
5.Bad VAS5054A Patch
5a.Softing_PDU-API_1.20.42 for clones
EN SFD-Manual for UMB.pdf
EN Windows 7 Announcement UMB.pdf
supportnews-en.pdf
Mega Tool Academy
Torrent 2
4.ODIS-Service_update_5_2_6-EU_20200317_98.0.140
Size: 44KB
Torrent 3
ODIS-Service_update_5_2_6-EU_20200330_98.0.160
Size: 39KB
Torrent 4
4a.ODIS-Service_update_5.1.6_v89.5.520 to 5.2.6-EU_20200303_96.0.10

Size: 16KB

Torrent 5
4b.ODIS-Service_update_5.1.6_v89.5.520 to 5.2.6-EU_20200317_98.0.140
Size: 15KB
Win10-VAS5054-ODIS-S-526:
How to install VAS 5054A, VAS 6154 ODIS 5.26?
Here is the installation guide on Win7 32 bit for reference.
The installation guide for VAS5054a and VAS-6154 are same. The difference is that it requires to install VAS driver for VAS6154.
VAS 5054A ODIS 5.26 install video
VAS 6154 ODIS 5.26 install video
Note: It will take a long time to copy the 5 software from DVD to the local disk of computer, please keep patient.
Main steps:
Step 1: Install OffboardDiagSetup-service_VWMCD_5_2
Step 2: Install Offboarddiaglauncher
Step 3: Run Offboard Diagnostic information system
Step 4: Install ODIS 5.26 patch
In detail…
Depends on your need to update windows system
Step 1: Install OffboardDiagSetup-service_VWMCD_5_2
Select a language
Choose target folder
Select diagnostic interface: VAS 5054 or VAS 6154
Click “Search” to select the related license
Install Offboard Diagnostic information system service success
Step 2: Install Offboarddiaglauncher
Copy the offboardDiagLauncher from local disk to program files (x86)
Step 3: Run Offboard Diagnostic information system
Right click “Offboard Diagnostic information system” to run as administrator
Open “keygen” option
Get the hardware ID and name from “Offboard Diagnostic information system
5.23 Registration Dialog” to the corresponding positions in the “Keys Generator”
Then obtain the registration key and paste to “Registration Dialog” to register
Input Postsetup configuration data
URL: Click “Select local directory” to choose
User name: abc
Kerword: abc
Select the corresponding language and download ODIS data
Restart computer
Step 4: Install ODIS 5.26 patch
Copy ODIS 5.26 patch to C disk
Mega Tool Drills
Install ODIS 5.26 software succeed
Then you can start to diagnose…
ODIS 5.2.6 Postsetup 98.0.210 tech support: www.cardiagtool.co.uk